The CADD-Solis VIP ambulatory infusion pump is a compact, portable device designed for precise medication delivery in various clinical settings, ensuring patient safety and operational efficiency.
Overview of the CADD-Solis VIP Ambulatory Infusion Pump
The CADD-Solis VIP ambulatory infusion pump is a portable, battery-operated device designed for precise medication delivery in clinical settings. It supports continuous and bolus infusions, making it ideal for pain management and other therapies. The pump is intended for use in hospitals, outpatient care, and home settings, offering flexibility and reliability. Clinicians can program specific delivery protocols, ensuring tailored treatment for patients. Its compact design and user-friendly interface enhance patient mobility and care efficiency. The pump requires clinician oversight, and detailed instructions are provided in the operator’s manual for safe operation.
Key Features and Applications of the Pump
The CADD-Solis VIP pump offers precise medication delivery with continuous and bolus infusion options, ideal for pain management and various therapies. It supports multiple delivery methods, including PCA, clinician bolus, and patient-controlled doses. The pump is compatible with IV, epidural, and subcutaneous administrations, providing flexibility in clinical applications. Its advanced features allow customization of protocols for specific therapies, ensuring tailored treatment plans. Designed for ambulatory use, the pump enhances patient mobility while maintaining therapy adherence in both hospital and home settings.
Important Safety Information
The CADD-Solis pump is not for blood or cellular blood product delivery. Use only under medical supervision. Follow manual instructions to avoid serious injury or death.
Warnings and Contraindications for Pump Usage
The CADD-Solis pump is contraindicated for blood or cellular blood product delivery, as these can cause severe complications. Use only under medical supervision. Patients should not access the operator’s manual, as it contains sensitive information. Always follow the instructions carefully to avoid risks of death or serious injury. The pump is not intended for unsupervised patient operation. Ensure proper training and adherence to clinical guidelines before use. Failure to comply may result in adverse outcomes;
Precautions for Clinicians and Patients
Clinicians must ensure proper training before operating the CADD-Solis pump. Patients should be closely monitored during infusion therapy. Always prime the tubing correctly to prevent air bubbles. Use only approved administration sets to maintain safety. Keep the pump upright to ensure accurate medication delivery. Regularly inspect the pump and tubing for damage or leaks. Clinicians should review the operator’s manual thoroughly. Patients must avoid tampering with the pump or altering settings. Proper precautions ensure safe and effective therapy delivery.
Setting Up the Pump
Insert batteries and prepare the medication cassette or administration set. Place the pump upright on a firm, flat surface for stable operation. Ensure all components are securely attached before starting the infusion process.
Inserting Batteries and Powering On the Pump
Insert four AA batteries into the pump, ensuring the + and ‒ markings align correctly. Close the battery compartment securely; Press the power button to turn the pump on. The display will activate, prompting you to start a new patient profile. If no buttons are pressed for 30 seconds, the screensaver mode begins to conserve battery life. Press any button to reactivate the display and continue setup. Always use fresh batteries for reliable operation, even when using an external power source.
Preparing the Medication Cassette or Administration Set
Filled medication cassettes or administration sets with fluid bags must be prepared before use. Ensure all air bubbles are removed from the tubing by gently squeezing. Attach the administration set to the cassette, making sure all connections are secure. Prime the tubing according to the instructions in the operator’s manual to ensure proper fluid flow. Always use a new administration set to prevent contamination and maintain sterility. Once prepared, the cassette or administration set is ready to be attached to the pump for infusion.
Programming the Pump
Insert batteries and power on the pump. Start a new patient profile, enter infusion rates, and use the keyboard access code. Key features include continuous and bolus delivery options.
Starting a New Patient Profile
To begin, insert batteries and power on the pump. The device will prompt you to start a new patient profile. Press “Yes” to proceed. Enter the patient’s details and therapy parameters using the keypad. Set the desired infusion rates and delivery method. Ensure all settings are confirmed before starting. The pump will guide you through the process, ensuring accurate and safe medication delivery. Always verify settings with a healthcare professional before initiating therapy.
Setting Up Continuous and Bolus Infusion Rates
Enter the desired continuous infusion rate using the keypad, ensuring units are correctly set (e.g., mL/hr). For bolus dosing, specify the bolus amount, interval, and lockout period. Review all settings on the display screen and confirm. The pump will calculate and store the parameters. Ensure rates align with the patient’s prescribed therapy. Always double-check entries for accuracy before saving. Proper setup ensures precise medication delivery, enhancing patient safety and treatment effectiveness.
Operating the Pump
Attach the prepared cassette securely to the pump. Prime the tubing according to the manufacturer’s guidelines. Start the infusion and monitor the delivery closely to ensure accuracy and patient safety.
Attaching the Cassette and Priming the Tubing
To attach the cassette, place the pump upright on a firm surface. Align the cassette hooks with the pump’s hinges and press down gently until it clicks securely into place. Ensure the cassette is tightly fitted against the pump to avoid any movement during operation. Next, prime the tubing by following the on-screen instructions. The pump will guide you through the priming process, ensuring air bubbles are removed and the tubing is properly filled with medication. This step is critical for accurate drug delivery and patient safety.
Starting the Infusion and Monitoring Delivery
Once the cassette is securely attached and the tubing is primed, press Yes on the keypad to begin the infusion. The pump will start delivering medication according to the programmed settings. Monitor the display for real-time status updates, including volume delivered and remaining battery life. Regularly check for any alarms or alerts, such as air in the tubing or low battery warnings. Ensure the tubing is properly secured to the patient to maintain continuous delivery. Refer to the manual for troubleshooting any issues during infusion.
Alarms and Troubleshooting
The CADD-Solis pump features high-priority alarms that stop operation if critical issues arise, such as air in tubing or blockages. Refer to the manual for resolving specific error messages and ensuring patient safety during infusion.
Understanding High-Priority Alarms and Resolving Issues
The CADD-Solis pump emits high-priority alarms for critical issues like air in tubing or blockages, requiring immediate attention. These alarms halt operation to prevent complications. Common issues include air in the tubing, cassette misalignment, or excessive pressure. To resolve, check the tubing for air, ensure the cassette is securely attached, and verify proper priming. Refer to the operator’s manual for specific troubleshooting steps and error message interpretations. If issues persist, contact Smiths Medical support for assistance. Always prioritize patient safety during resolution.
Common Error Messages and Solutions
The CADD-Solis pump displays specific error messages to indicate issues. Common errors include “Air in Tubing” or “Cassette Misaligned,” often due to improper setup. To resolve, inspect tubing for air bubbles, ensure the cassette is securely attached, and restart the pump. For “Low Battery” alerts, replace or recharge batteries promptly. “Keypad Locked” messages require entering the access code or using the pump key. Always refer to the operator’s manual for detailed solutions or contact Smiths Medical support for unresolved issues to ensure safe and effective operation.
Maintenance and Troubleshooting
Regularly clean the pump with alcohol pads and inspect for wear. Resetting to factory settings can resolve software issues, ensuring optimal performance and patient safety.
Cleaning and Caring for the Pump
Use 70% isopropyl alcohol pads to clean the pump’s exterior and battery compartment. Avoid harsh chemicals or abrasive materials. Wipe down surfaces gently, ensuring no moisture enters openings. Dry thoroughly before use. Regular cleaning prevents contamination and maintains functionality. Do not submerge the pump in water. Proper care extends the pump’s lifespan and ensures reliable operation for patient safety.
Resetting the Pump to Factory Default Settings
To reset the CADD-Solis pump to factory default settings, navigate to the “Setup” menu and select “Factory Reset.” Use the pump key or enter the keyboard access code to confirm. This process will erase all custom settings, returning the pump to its original configuration. After resetting, power off the pump, then turn it back on to ensure proper initialization. Note that resetting will not delete recorded infusion data but will restore default parameters for programming. Always reprogram the pump with the correct settings before use.
Advanced Features and Customization
The CADD-Solis pump offers advanced customization options, enabling multiple delivery methods for pain management and tailored therapy protocols to meet specific clinical needs.
Using Multiple Delivery Methods for Pain Management
The CADD-Solis pump supports multiple delivery methods for pain management, including continuous infusion, bolus doses, and patient-controlled analgesia (PCA). This versatility allows clinicians to tailor therapy to patient needs, combining methods for optimal pain relief. Continuous infusion provides a steady medication flow, while bolus doses offer additional relief as needed. PCA empowers patients to administer predefined doses within safe limits. Customizable settings, such as bolus dose limits, lockout intervals, and delivery rates, ensure personalized and effective pain management strategies. This flexibility enhances patient comfort and clinical outcomes.
Customizing Protocols for Specific Therapies
The CADD-Solis pump allows clinicians to customize infusion protocols for specific therapies, ensuring precise and targeted medication delivery. Protocols can be tailored for therapies such as antibiotic delivery, chemotherapy, or pain management. Adjustable settings include infusion rates, bolus doses, and lockout intervals, enabling personalized treatment plans. The pump’s user-friendly interface simplifies the creation of custom protocols, while maintaining safety and efficacy. This flexibility ensures that therapy is optimized for individual patient needs, improving outcomes and minimizing adverse effects. Customization options enhance the pump’s adaptability across diverse clinical applications.
Appendices
The appendices provide essential references, including technical specifications, device information, and a glossary of terms. These sections offer detailed insights into the pump’s operational and technical aspects.
Technical Specifications and Device Information
The CADD-Solis VIP pump operates on 4 AA alkaline or nickel-metal hydride batteries, ensuring up to 40 hours of continuous use. It supports a wide range of infusion rates, from 0.1 mL/hr to 1000 mL/hr, and is compatible with various administration routes, including IV, subcutaneous, and epidural. The pump features a 3.5-inch color screen for easy navigation and weighs approximately 1.2 pounds, making it highly portable. It is designed to function in temperatures between 50°F and 104°F (10°C to 40°C) and humid environments up to 95% RH. The device complies with FDA and CE certifications, ensuring safety and reliability in clinical settings.
Glossary of Terms and References
Ambulatory Infusion Pump: A portable device delivering medication outside a clinical setting. Bolus Dose: A single, large dose administered on demand. Continuous Rate: Steady medication delivery over time. PCA (Patient-Controlled Analgesia): Allows patients to self-administer pain relief within set limits. Priming: Preparing tubing for infusion by clearing air. Alarms: Alerts for issues like occlusions or low battery. Cassette: Holds medication and connects to the pump. Flow Rate: Volume of medication delivered per hour, measured in mL/hr.